Construction Formula
  • 20 Sep 2023
  • 4 Minutes to read
  • Dark
    Light
  • PDF

Construction Formula

  • Dark
    Light
  • PDF

Article Summary

Before reading this article, ensure you have read Measurement - Parts & Labour and Using Formula within Groundplan articles to aid in understanding the following Formula examples.

📝 The Formula values provided in this article are for example purposes only.

TermExplained
counttotal counts
lentotal metres measured
areatotal square metres measured
count, len or area / xtotal count/length/area divided by an amount
count, len or area * xtotal count/length/area multiplied by an amount
+ len * xadd the perimetre of the area drawn multiplied by an amount
ceil(x)rounding up a decimal value to the next whole number


Internal Door

Measurement Part Formula examples to calculate a 2040mm x 820mm x 35mm internal door using a Count Measurement:

carpentry-door.png

PartExplanationFormulaUMO
Internal Door 2040mm x 820mm x 35mmDoors countedcounteach
Gainsborough G3 series satin chromeHandles requiredcounteach
HingesNumber of hinges required for 3 hinges per doorcount*3each
Rebated door jamb (5.4m length)Number of 5.4 lengths required for each doorcountlengths
Bevelled edge architrave 42mm x 11mm (5.4m length)Number of 5.4 lengths required for each side of the doorcount*2lengths


Framing

Example Parts for frame including bottom, top and ribbon plates, noggins and studs @450mm spacing (2.4m lengths) Length Measurement:

construction-framing.png

PartExplanationFormulaUMO
MGP 10 Framing pine H2 90mm x 35mm (2.4m lengths)The total length measured divided by lengths of 2.4m multipled by *4 for bottom plate, noggins, top and ribbon plates, added to the total length measured divided by studs every 450mm(len/2.4*4) + (len/0.45)lengths


Cladding

Example Parts for Primeline Newport 4200mm x 170mm x 9mm Area Measurement:

construction-cladding.png

PartExplanationFormulaUMO
Primeline Newport 4200mm x 170mm x 9mm (0.588m2 coverage)Total area measured after doors and windows were removed divided by 0.588m2 of board coverageceil(area/0.588)boards


Brickwork

Example Parts for standard brickwork Area Measurement:

construction-brickwork-area.png

PartExplanationFormulaUMO
Brickwork StandardArea of brickwork required after windows and doors were removedaream2
BricksHow many bricks are required after windows and doors were removed when 50 bricks fit into an average m2 and allow for 10% wastageceil(area*50*1.10)each


Concrete

Example Parts for a 150mm thickness concrete Area Measurement:

landscaping-concreting.png

PartExplanationFormulaUMO
Concrete 150mmHow much m3 of concrete is required for 150mm thicknessarea*0.15m3
FormworkHow many metres of formwork is required for the perimeter around the area measuredlenm
Steel mesh 4.56m x 1.97m (7.5m2 coverage)How many 7.5m2 coverage sheets are required for the area measuredceil(area/7.5)sheets
Bar chairs (pk500)How many chairs are required to support the steel mesh with 4 per m2 and come in a bag of 500ceil(area*4/500)bags


Strip Footings

Example Parts for a strip footings Length Measurement:

construction-strip-footings.png

PartExplanationFormulaUMO
TrenchHow many cubic metres required for the total length measured multiplied by 450mm width multiplied by 450mm depth and allow for 10% expansion(len*0.45*0.45)*1.10m3
ConcreteHow many cubic metres required for the total length measured multiplied by 450mm width multiplied by 450mm depth and allow for 10% expansion(len*0.45*0.45)*1.10m3


Decking

Example Parts for a Kwila Decking 90mm x 19mm (including 5mm gaps) Area Measurement:

construction-decking.png

PartExplanationFormulaUMO
Kwila Decking 90mm x 19mmHow many metres of decking boards are required when 10.52m covers 1 m2 with 5mm gaps and allow for 10% wastage(area*10.52m)*1.10m


Waterproofing

Example Parts for a waterproofing Area Measurement:

construction-waterproofing.png

PartExplanationFormulaUMO
Wet AreasTotal area measuredaream2
PrimerHow many Litres are required for the area measured plus 100mm up the wall around the perimetre of the area divided by an average of 1 litre based on covering 6m2(area+len*0.1)/6Litres
WP MembraneHow many Litres are required for the area measured plus 100mm up the wall around the perimetre of the area divided by an average of 1 litre based on covering 1.5m2 multiplied by 2 coats(area+len*0.1)/1.5*2Litres


Tiling

  1. Example Parts for Limestone porcelain 600mm x 600mm floor tiles Area Measurement:

construction-tiling.png

PartExplanationFormulaUMO
Limestone porcelain 600mm x 600mm floor tilesArea of tiles required after cabinets and islands benches were removedaream2
Limestone porcelain boxesHow many boxes are required when a box covers 1.44m2 and allowing for 20% wastageceil(area/1.44*1.20)boxes


  1. Example Parts for subway grey 200mm x 100mm wall tiles Length Measurement:

construction-tiling-wall.png

PartExplanationFormulaUMO
Subway grey wall tiles 100 x 200mmHow many m2 of tiles are required when the tiles are 600mm up the walllen*0.60m2
Subway grey boxesHow many boxes are required for the total length multiplied by 600mm up the wall when a box covers 1.14m2 and allowing for 10% wastageceil((len*0.6/1.14)*1.10)boxes


For Formula assistance, please reach out to Support for assistance. Go to: Help > Send us a Message.

Download a PDF copy of Using Formulas within Groundplan here.



💡Accessed your Company's free 1 hour Training Session?

Organise your session today! Click Help > Send us a Message and ask to book in for free training.

Trainers can assist with:

  • Workflow solutions
  • Time-saving tips
  • Making sure you're getting the most out of your subscription

If you've accessed your free training and need further Support, reach out to book a 1 or 2 hour paid session.



Was this article helpful?